Assay Development & Screening

Custom Assay Development & HTS Screening (ECHO Acoustic Liquid Handling)

De novo assay design, optimization and full method validation for novel and challenging drug targets — with assay miniaturization into 384- and 1536-well formats and low-compound-consumption high-throughput and focused screening on the ECHO acoustic liquid handler.

Assay Development & Screening work in the AXK Bio laboratory.
Overview

How this service works

Many emerging drug targets lack a commercial assay kit. We start from your molecule and your target and build a fit-for-purpose biochemical or cell-based assay from scratch, then optimize and validate it before any compound is screened against it.

The validated assay moves directly into ECHO acoustic liquid handling. Because the ECHO transfers compounds as tip-free, acoustically generated droplets, the format miniaturizes into 384- and 1536-well plates with minimal compound consumption — keeping the same detection format intact from first hit to confirmed dose-response. Assay transfer to other platforms and method troubleshooting are covered under the same scope.

Technique index

Formats and readouts covered by this service line.

  • De novo assay designNovel · Challenging
  • Assay optimization & validationZ′ · S/B · CV
  • ECHO acoustic miniaturization384 · 1536
  • Low-consumption HTS & focused screeningHTS · Focused
  • Assay transfer & troubleshootingTransfer · QC
  • Custom readout selectionHTRF · AlphaLISA · FP
What we run

Capabilities

The formats below are the working set for this service line. Where a programme needs a variation, the assay is adapted rather than forced into the closest existing format.

De novo assay design

Assay formats built from scratch for targets that have no commercial kit, matched to the chemistry of your molecule and target.

Novel · Challenging

Assay optimization & validation

Signal window, linearity and control performance tuned and locked before screening, with Z′, signal-to-background and CV reported for every validated format.

Z′ · S/B · CV

ECHO acoustic miniaturization

Transfer of the validated assay into 384- and 1536-well plates using acoustically generated droplets with no tips, keeping volumes and compound use to a minimum.

384 · 1536

Low-consumption HTS & focused screening

Primary high-throughput and focused screens that preserve the compound library for follow-up and dose-response work.

HTS · Focused

Assay transfer & troubleshooting

Moving an established format to another platform or plate density, and diagnosing degraded or non-responsive assays.

Transfer · QC

Custom readout selection

Absorbance, fluorescence, luminescence, HTRF, AlphaLISA and fluorescence polarization chosen against the target and the intended screen.

HTRF · AlphaLISA · FP

Screening platforms

The ECHO acoustic liquid handler is the core of the screening workflow, integrated with multimode microplate readers for the detection formats above. Source plates stay sealed and unchanged between runs, so re-testing a confirmed hit re-reads the original well rather than re-preparing the compound.

  • ECHO acoustic liquid handling for tip-free, low-volume compound transfer
  • 384- and 1536-well assay formats with matching low-volume detection
  • Multimode readers for HTRF, AlphaLISA, fluorescence polarization and luminescence
  • Environmental control for temperature- and evaporation-sensitive assays
Data package

What you receive

Raw instrument files are delivered alongside the processed tables, so any reported number can be traced back to the acquisition that produced it.

  • Validated assay protocol with Z′, signal-to-background and CV recorded
  • Miniaturized plate format and the acoustic transfer parameters used
  • Complete screening result table with raw and normalized values
  • Confirmed hit list with dose-response data
  • A non-GLP study report suitable for IND-supporting packages
  • Raw instrument files retained for independent re-analysis
Working detail

Study mechanics

The practical decisions that shape how a study in this service line is set up, run and reported.

  • Assay format selected against the target and the compound series
  • Enzyme, probe and compound concentrations optimized into a stable signal window
  • Z′, signal-to-background and CV assessed before the assay is released for screening
  • Positive, negative and vehicle controls established on every plate

Start a study

Send the target, the sample set and the decision the data needs to support. We will come back with a study plan covering the Custom Assay Development & HTS Screening (ECHO Acoustic Liquid Handling) format and the data package.

Request a quote